Service Information
  Last Updated:  8-December, 2003


Approved information and links to Official documents

Services Final Design Review   24-June-'03  CERN

This link contains all presentations and uploaded versions of all documents at the revision levels current at the time of the review

Services Document--ATL-IP-ES-0007

This link goes to EDMS, the versions tab of this document gives links to all versions of the Service Integration Document.

All information presented below is intended to be consistent with the above document, however this document will need updating to
include the information below.  This will be done as soon as the documents and information below have been reviewed

Information for comment and revision:


Service Connectivity:
Tables and figures defining connectivity from Module/Local support, through Service Panels, up to PP1b connectors are defined below.  
This is a work in progress, and will eventually be uploaded into official documentation in EDMS.


Geometry Definition Figures (powerpoint)  Helps to define geometry for figures below--will update as time allows to include all summary information
(UPDATED:  8-DEC-03)

Module to PP0
Tables Defining positions of modules and PP0 flex connections are defined.  Table nomenclature follows that defined in Services Document (link above)
Services document will need revision to include some new nomenclature and updated counts per octant...

The following two documents describe the Connectivity between the modules and PP0

ATL-IP-ES-0092 v5

This document describes the connectivity table layout and source data--the connectivity table is Appendix A to this document.

ATL-IP-ES-0092 Appendix-A v3

This is the native Excel spreadsheet:


Routing and position information used to calculate cable lengths in the above tables was taken from the following figures:
PP0_Connector_Locations.pdf--Defines Z-location of every connector on PP0
atl-ip-ed-0155.pdf--Defines Z-Location of all stave connectors, used to define center module (M0) connector postion
SECTOR_MODULE_LAYOUT.pdf
--Defines additional routing distance on each sector added to cable length based on module #

PP0 to PP1b:
Tables and figures defining connection of services from PP0 Flex out to PP1b connectors through PP1 penetration flexes.
These documents define the different PP1 penetration flexes required, and map PP1b connectors (LEMO) to PP0  
Indicial location references for the PP0 flex and PP1b connector locations are defined.

Service Quarter Panel Connectivity
The files below are tables of connectivity between PP0 and the connectors at PP1b.  They are an expansion of the above tables
and include mapping of all PP0 flexes to every PP1b flex.  Also included is the name of the local support serviced

ATL-IP-ES-0093 v5

Document describing layout of Service Quarter panels as well as how to read connectivity tables included in appendix below  

ATL-IP-ES-0093_AppendixA_V4

Native Excel Spreadsheet, Appendix to above Document


Optical Fiber Connectivity--First Draft
The files below are draft.  The table below shows the mapping of all Service Quarter Panels, and includes some data for ROD Mapping.  Every quadrant has identical fiber
routing, that is each PP0 flex position on the service panels maps directly to a given position in the Ericsson Connector at PP1.  This mapping is identical for all quadrants.  The only difference between quadrants is mapping of local support to specific PP0 flexes in a given octant.  The table includes the connection and naming of the internal fiber double-pigtails (PP0 to PP1),  as well as the enumeration of Cables external to PP1.  It is intended to include mapping all the way to the ROD, that is this table will have Module to ROD mapping in one table, down to the unique designation of fibers within each ribbon.  Currently, this ROD mapping table is in work.

ATL-IP-ES-0102 v3

Document describing the layout and connection scheme of the Optical connection table

Opto Connectivity Table

PP0 to Connector map complete--cross-referenced local supports not updated